Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-87
2-Way Slip-In Cartridge Valves
Series C10C*E***
C10 UK.indd TS 02.10.17
Orifices (see 'Accessories')
Characteristics / Ordering Code
The 2/2-way seat valves series C10C*E are equipped
with an inductive switch to monitor the closed position.
The poppet has a 60/40 area ratio (AA = 0.6 AC, AB =
0.4 AC) and is capable for flow in both directions.
The safety overlap of the poppet avoids opening of
the valve before the signal of the inductive switch has
changed.
For sizes NG80 and NG100 a proximity switch is used.
Features
German trade association certificate No. HSM 16014
8 sizes, NG16 up to NG100
Cover to mount a directional control valve (on the side)
for cover 3 (for NG16 to NG63)
Cavity and mounting pattern acc. to ISO 7368
Monitored closed position
Inductive switch CE conform
Optional with poppet sealing between pilot flow C and
port B
Ordering code
2/2-way
valve
Nominal
size
1)
NG16 to NG63. The DC valve is not included in the delivery.
We recommend the following pilot valves: D1VW020BN*W or D1VW020HN*W,
depending on the required functionality and plug location.
2)
Only with spring S, T and U.
Code S
with seal
1
X
Orifice
1
2
3
4
SealNominal opening
pressure spring
Code Seal
N NBR
V FPM
C
Code Orifice
ohne
no orifice
(2-4 cover 1)
00 Plug
99 open, without orifice
Code Cover
1
without pilot valve
interface
3
1)
with pilot valve
interface
Code Nominal size
016 NG16
025 NG25
032 NG32
040 NG40
050 NG50
063 NG63
080 NG80
100 NG100
10
Poppet shape
60/40
C
Ind. monitoring
hydraulic
operation
Cover
E
Slip-in
cartridge
ISO 7368
Poppet
seal
Code Poppet seal
C without
S
2)
with
Code
Nominal opening
pressure spring
L 0.1 bar
N 0.5 bar
S 1.6 bar
T
2.5 bar
U 4.0 bar
Cover 1 Cover 3
C10C1E
B
A
C
X
1
G
B
A
C
Z1
X
YZ2
12
3
4
B
T
A
P
T
P
B
A
G
C10C3E
Design
series
(not required
for ordering)
Please order female connector M12x1
separately (order no. 5004109)
Note: X modifications are not certified.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-88
C10 UK.indd TS 02.10.17
2-Way Slip-In Cartridge Valves
Series C10C*E***
Characteristic curve measured with HLP46 at 50 °C.
General
Design 2-way slip-in cartridge valves ISO 7368
Size
NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Operation hydraulic
Ambient temperature [C°] -20...+60
MTTF
D
value [years] 150
Weight [kg] 1.5 2.7 4.3 7.4 12 23 53 89
Hydraulic
Max. operating pressure
[bar] 350
Nominal flow p 5 bar [l/min] 230 400 800 1250 1625 3400 5000 7500
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [C°] -20...+70 (NBR: -25...+70)
Viscosity, permitted
recommended
[cSt] / [mm²/s]
[cSt] / [mm²/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Control volume at max. stroke [cm³] 2.03 6.45 12.21 20.32 39.40 94.56 218 374
Control surface (surface C = 100 %) A/B [%] approx. 60 / 40 related on surface C
Opening pressure
flow direction A—>B
flow direction B—>A
[bar]
[bar]
Spring: L = 0.2; N = 0.9; S = 2.7; T = 4.0; U = 6.6
Spring: L = 0.3; N = 1.3; S = 4.0; T = 6.3; U = 10.0
Electrical (Inductive switch)
See position control
Technical data
Technical Data / Characteristic Curve
p/Q performance curve
(without spring and poppet seal, C-chamber unloaded)
Recommended orifice diameter
Depending on function, plugs must be used (code00).
Cover Orifice NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
C10C1E No.: 1 1/16 NPT 1/16 NPT 1/16 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT
C10C3E No.: 1, 2, 3, 4 M5 M6 M6 M6 M8 M8 n/a n/a
Inlet orifice Ø 0.8 Ø 1.2 Ø 1.5 Ø 2.0 Ø 2.5 Ø 3.0 Ø 3.0 Ø 3.0
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-89
2-Way Slip-In Cartridge Valves
Series C10C*E***
C10 UK.indd TS 02.10.17
b1
3.5
h2
X
h1
t2
H
Ød1
Ød2
No defined position for
female connector.
29.5
Dimensions
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
Seal and bolt kits
Cavity and mounting pattern acc. to ISO 7368
Dimensions C10C1E
NG16 to NG63
1)
NG80 to NG100
1)
NG H h h2 b1 d1 d2 t
+0.1
16 107 36 28 65 32 25 56
25 116 45 32.5 85 45 34 72
32 122 50 32 102 60 45 85
40 131 60 40 125 75 55 105
50 141 70 45 140 90 68 122
63 156 85 55 180 120 90 155
80 195 105 80 250 145 110 205
100 210 120 89 300 180 135 245
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Nominal size 16 25 32 40 50 63 80 100
Seal kit FPM
SK-
C10C1E16V
SK-
C10C1E25V
SK-
C10C1E32V
SK-
C10C1E40V
SK-
C10C1E50V
SK-
C10C1E60V
SK-
C10C1E80V
SK-
C10C1E100V
NBR
SK-
C10C1E16N
SK-
C10C1E25N
SK-
C10C1E32N
SK-
C10C1E40N
SK-
C10C1E50N
SK-
C10C1E60N
SK-
C10C1E80N
SK-
C10C1E100N
Bolt kit
[ISO 4762-12.9]
BK414
4x M8x40
BK391
4x M12x50
BK415
4x M16x55
BK416
4x M20x70
BK417
4x M20x75
BK418
4x M30x100
BK419
8x M24x120
BK420
8x M30x140
Recommended torque [Nm] 31.8 108 264 517 517 1775 890 1775
The space necessary to remove the M12x1 female connector is at
least 22 mm.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-90
C10 UK.indd TS 02.10.17
2-Way Slip-In Cartridge Valves
Series C10C*E***
t2
H
h3
h2
h1
Z2 Z1XY
b2
Ød1
Ød2
3.5
b1
3.5
29.5
No defined position for
female connector.
Cavity and mounting pattern acc. to ISO 7368
NG63
1)
Pilot valve interface NG10.
Dimensions
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
Seal and bolt kits
Cavity and mounting pattern acc. to ISO 7368
Dimensions C10C3E
NG16 to NG50
1)
Pilot valve interface NG06.
Lifting eye bolt
M12-DIN 580
Ød2
Ød1
3.5
3.5
b2
b2
H
h3
h1
h2
t2
Z2 Z1
b1
T
A
P
B
4
No defined position
for female connector.
29.5
Nominal size 16 25 32 40 50 63
Seal kit FPM SK-C10C3E16V SK-C10C3E25V SK-C10C3E32V SK-C10C3E40V SK-C10C3E50V SK-C10C3E63V
NBR SK-C10C3E16N SK-C10C3E25N SK-C10C3E32N SK-C10C3E40N SK-C10C3E50N SK-C10C3E63N
Bolt kit
[ISO 4762-12.9]
BK533
4x M8x90
BK532
4x M12x90
BK526
4x M16x80
BK527
4x M20x80
BK534
4x M20x90
BK536
4x M30x120
Recommended torque
± 15%
[Nm] 31.8 108 264 517 517 1775
NG H h1 h2 h3 b1 b2 d1 d2 t2
16 156 85 76 72 65 15.5 31 25 56
25 156 85 70 72 85 15.5 45 34 72
32 156 85 56 72 102 15.5 60 45 85
40 156 85 50 72 125 15.5 75 55 105
50 156 85 60 72 140 15.5 90 68 122
63 181 110 75 91 180 21.5 120 90 155
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
The space necessary to remove the M12x1
female connector is at least 22 mm.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-91
2-Way Slip-In Cartridge Valves
Series C10C*E***
C10 UK.indd TS 02.10.17
German trade association certificate
Certificate
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-92
C10 UK.indd TS 02.10.17
2-Way Slip-In Cartridge Valves
Series C10C*E***Position Control
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG16 to NG63
M12 pin assignment
1 + U
S
19.2...28.8 V
2 Out B: normally open
3 0V
4 Out A: normally closed
Please order plug M12x1 separately (see accessories directional control valves, plug M12x1; order no.: 5004109)
Supply voltage [VDC] 24
Tolernace supply voltage [%] ±20
Ripple supply voltage [%] 10
Polarity protection [V] 300
Current consumption without load [mA] 20
Switching hysteresis [mm] <0.06
Max. output current per channel, ohmic [mA] 250
Ambient temperature [°C] -20 … +60
Protection IP65 acc. EN 60529
CE conform
1)
EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6 1) / ENV 50140 / ENV 50204
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
AC
DC
1
4
2
3
DC
DC st
O
SZ.
U
S
Out
GND
Out neg.
Outputs: Open collector
2
1
3
4
1)
Only guaranted with screened cable and female connector
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-93
2-Way Slip-In Cartridge Valves
Series C10C*E***
C10 UK.indd TS 02.10.17
Position Control
Protection class IP65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] -20...+60
Supply voltage U
S
/ ripple [V] 10...30 / 10 %
Current consumption without load [mA] 10
Max. output current per channel, ohmic [mA] 200
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V] 2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1
Wiring min. [mm²] 3 x 0.14 braid shield recommended
Wiring length max. [m] 50 recommended
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG80 to NG100
M12 pin assignment
1 + U
S
10...30 V
2 Out A: not connected
3 0V
4 Out A: normally closed
Definition
Start position monitored:
The switching point of the inductive switch is within the
overlap of the poppet.
After the signal of the inductive switch has changed, the
poppet leaves the safety overlapping position.
Please order plug M12x1 separately. Straight plug recom-
mended – no defined position possible for angled plug.